Hotline

0512-65362962

PRODUCT

PRODUCT
  • 0512-65362962
  • Mr. Zhang
  • 13606138871
  • Mr. Ji
  • 18651111651
  • xinye@xcl-sz.com
  • No.185-18, Songshan Road, Suzhou
Location:

Home > Product

Semi-rigid flame retardant high-electricity PVC sheath material for high-voltage cable

【Update】:2020/5/13    【Source】:SuZhou New District XinYe Special Cables Material Factory

Semi-rigid flame-retardant high-electricity PVC sheath material for high-voltage cables


♦ Product name, model, purpose

Product Number

Product Name

Features and Uses

BYZR-PVCH90

90℃ flame-retardant semi-rigid high-electricity PVC sheath for 110KV   and above

Specially designed for high-voltage   cables, insulation aging is better than other PVC, easy to process.

DDZR-PVCH90

90℃ low-smoke, low-halogen, flame-retardant, high-electricity PVC   sheath for 110KV or higher

Specially designed for high-voltage   cables, insulation aging is better than other PVC, easy to process.

 

♦ Product Manual:

The product of this project is a cable material made of polyethylene resin as the base material, adding plasticizers, stabilizers, flame retardants, smoke suppressants and other additives, and then mixing, plasticizing and granulating.

 

♦ Product Performance:

Typical values are shown in Table (6)

 

♦ Reference Standard:

GB/T8815-2002 or user standard.

 

♦ Processing Technology:

The product of this project is suitable for ordinary PVC screw type 150~200 to obtain a good extrusion process.

The recommended temperature is as follows:

 

District

1

2

3

4

5

6

7

8

Nose

Temperature ℃

155

165

170

175

178

180

185

185

185

 

♦ Product packaging, Storage and Transportation:

The project adopts paper-plastic composite moisture-proof packaging, and the net weight of each bag is (25kg±0.2). The material is 40 bags for a set of tons of packaging and wooden pallets with PE film to seal against moisture, rain and sun. Keep a clean environment intact for easy transportation. The normal temperature of the warehouse is around 0℃~35℃, and the storage period of the products should not exceed one year from the date of production.

 

♦ Product Performance

Table(6)


Pilot Projects

Category

90℃   flame-retardant semi-rigid high-electricity PVC sheath

90℃   low-smoke, low-halogen, flame-retardant, high-electricity PVC sheath

BYZR--PVCH90

DDZR-PVCH90

GB standard test method

Unit

Standard value

Typical value

Standard value

Typical value

Density

g/cm3

≤1.42

1.4

≤1.58

1.56

Tensile Strength

Mpa

≥20

25

≥16

20.5

Elongation at break

%

≥220

310

≥180

250

Air aging box

℃×h

100×240

passed

100×240

passed

Tensile strength change rate

%

±10

5

20

7

Change rate of elongation at break

%

±15

-7

±20

-10

20℃   volume resistivity

Ω·m

5×1012

7.8×1012

1×1012

2.5×1012

Embrittlement temperature

℃

-15

passed

-15

passed

Dielectric Strength

MV/m

≥20

28

≥20

25

Oxygen Index

%

≥30

30.5

≥30

30.8

Thermally stable at 200°C

Min

≥150

160

≥80

100

Thermal weight loss

g/cm2

≤18

15

≤15

13

HCL Content


—

—

≤150

passed

Smoke density flameless method

≤

—

—

≤300

passed

Smoke density smoke method

≤

—

—

≤300

passed

Shore D hardness

—

50-55

53

50-55

50


Note: The typical value cannot be regarded as the standard of the specification limit or the design basis separately quoted. It can also be made into a "antproof" sheath according to user needs. The color is determined according to user needs.